  1. LASER WIRE GAUGE

    Laser wire gauges are available for diameter measurements based on a scanning principle for larger diameters and diffraction setup for smaller diameters.


    Diffractive and scanning laser wire gauge
    Figure 1: Diffractive (left) and scanning (right) laser wire gauge (www.cortex.hu)

    Typical parameters are beam diameters of ~0.1 mm and sampling rates of 2,000 readings per second. In the drawing process of wires and other products these gauges are indispensable due to their precision and robustness. The beam diameter corresponds with the ability to detect small protrusions on the wire surface.